SM 1222(16DO)
6-Digital Output Modules,DQ16 x 24VDC,Transistor.
- Model no.
- SM 1222 16DO
- Order No.
- F7 222-1BH32-0XB0
- Product Description
- 16-Digital Output
- Product Size
- 45x100x75mm
Product Advantages
- Fully compatible with the Siemens S7-1200 PLC series,allowing direct replacement of original expansion modules.
- Module configuration in TIA Portal is identical to that of the corresponding original series modules.
- Module wiring methods are consistent with the original series modules.
- Supports CPU main units of all software versions in the original series.
- Output channels support output freeze function when the CPU is in STOP mode.
- Supports configurable analog outputs.
- Supports configurable digital inputs and outputs.
- Backplane communication adopts 40 Mbps high-speed LVDS communication technology, featuring fast transmission speed and strong anti-interference capability.
- Input channels support noise suppression and filtering functions.
- Input channels support over-range,under-range,and wire-break diagnostics.
- Output channels support over-range,under-range,short-circuit,and open-circuit diagnostics.
- Integrated port protection circuits enhance safety;analog voltage input ports can withstand voltages up to 300 V.
- Analog signal acquisition adopts advanced filtering algorithms,achieving fast response and stable performance.
- Analog input ports utilize differential sampling technology,improving common-mode interference resistance up to 150 V.
- Digital input and output ports feature enhanced voltage tolerance up to 60 V,ensuring reliable operation.
- Uses corrosion-resistant gold-plated industrial-grade PCB boards with a special conformal coating to withstand harsh operating environments.
Add galvanic isolation

Without Electrical Isolation
Without electrical isolation, excessive current at the module port will be transmitted through the backplane to allPLC modules on the rack, resulting in damage.

With Enhanced Electrical Isolation
With enhanced electrical isolation, excessive current at the module port willnot be transmitted through thebackplane to other PLC modules on the rack, providing effective protection.

PCB Finish: Immersion Gold (ENIG) with custom conformal coating
Product Features

Fully compatible with original software and hardware.
Fully hardware compatible, allowing seamless integration with original CPUs and modules while keeping engineers’ familiar workflows unchanged.

Reverse polarity protection
The module's power input ports feature reverse polarity, overvoltage, and overcurrent protection. The analog voltage acquisition ports withstand up to 300 V, preventing damage even under direct connection to 220 VAC mains supply.

Precision Analog Performance
Both analog inputs and outputs utilize 16-bit industrial-grade ADC and DAC chips. Powered by proprietary digital filtering algorithms, the module delivers superior "4-High" performance: high precision, high linearity, high resolution, and ultra-fast response speed.

Advanced Diagnostics & Fail-Safe Control
Supports configurable filter depth, along with over-limit alarms, wire-break detection, and customizable output behavior in STOP mode, including output freeze and predefined state configuration.
Product dimensions

- Product dimensions as indicated above.
| Operating Specifications | |
|---|---|
| Model no | SM 1222 16DO |
| Article No | F7 222-1BH32-0XB0 |
| Description | 16-Digital Output,DQ16 x 24VDC |
| Dimensions WxHxD(mm) | 45×100×75mm |
| Power Consumption | 10W |
| Available current(SM bus) | 180mA |
| Available current(Sensor power 24V) | 4mA for each input point used, each relay coil used is 11mA |
| Digital Input | |
| Number of Inputs | 16 |
| Input Type | The sinking /sourcing type |
| Surge Voltage | 35VDC, lasting 0.5s |
| Logic 1 Signal (Min) | Logic 1 Signal (Min) |
| Logic 0 Signal (Max) | 5V DC at 1mA |
| Optical Isolation (field side and logic side) | 500 V AC, lasting 1 min |
| Isolation Group | 2 |
| Filter Time | 0.2, 0.4, 0.8, 1.6, 3.2, 6.4 and 12.8 ms(optional, 4 inputs form one group ) |
| Digital Output | |
|---|---|
| Number of Outputs | 16 |
| Output Type | Relay, dry contact |
| Voltage Range | 5-30V DC or 5-250V AC |
| Logic 1 Signal at Maximum Current | —— |
| Logic 0 Signal with 10KΩ Load | -—— |
| Electric Current(Max) | 2A |
| Lamp Load | 30W DC/200W AC |
| Flood Leakage Current of Each Point | -—— |
| Surge Current | it is 7A when the contact is closed |
| Isolation (field side and logic side) | 1500V AC, lasting 1 min(Coil and contact); |
| None(coil and logic side ) | |
| Isolation Group | 4 |
| Current of Each Public Terminal (Max) | 8A |
| Switching Delay | Up to 10ms |
| Mechanical Lifetime (non-responsible) | 10,000,000 break/close cycles |
| Lifetime under Rated Load | 100,000 break/close cycles |
| Behavior at RUN-STOP | previous value or replacement value (default is 0) |